Bosca SOUL 700 Bedienungshandbuch

Stöbern Sie online oder laden Sie Bedienungshandbuch nach Herde Bosca SOUL 700 herunter. Bosca SOUL 700 Owner`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Save These Instructions
Please read this entire manual before you install and use your BOSCA SOUL 700 Pellet Stove.
Failure to follow instructions may result in property damage, bodily injury, or even death.
Owner´s Manual
SOUL 700 Pellet Stove and Insert
Installation and Operating Instructions
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - Owner´s Manual

Save These InstructionsPlease read this entire manual before you install and use your BOSCA SOUL 700 Pellet Stove.Failure to follow instructions may r

Seite 2 - OWNER’S MANUAL

7.- HOPPER DOOR ASSEMBLY (fig. Nº8)8.- BACK PANEL ASSEMBLY (fig. Nº9)fig. Nº8fig. Nº9a.- Unpack hopper door assembly.b.- Place hopper top over hopper.

Seite 3 - TABLE OF CONTENTS

The BOSCA SOUL 700 Pellet Stove has been tested and listed for installation in residential, mobile homeand alcove applications.fig. Nº10NOTE: ceramic

Seite 4 - INTRODUCTION

fig. Nº12WALL CLEARANCES(76 mm.)3 in.7 in.3 in.(76 mm.)Back wallSide wallfig. Nº11FRONT VIEWTOP VIEWDO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN T

Seite 5 - SAFETY PRECAUTIONS

If outside air is not used, it is important that combustion air is easily available to the air inlet. A closeable outside air register canbe used in t

Seite 6

EQUIVALENT VENT LENGTH (EVL)The longer the run of pipe in your installation, the more restrictions there is in the system. Therefore, larger diameter

Seite 7

fig. Nº14fig. Nº15GALVANIZED EXTERIOR(STAINLESS STEEL FORCORVENT)BLACKINTERIORFig 14. Locate terminations:a) not less than 3 feet above any forced air

Seite 8

VERTICALLY WITH NEW CHIMNEY SYSTEM( Refer to Figures 16a-16b)fig. Nº16b4 FT.fig. Nº16a24" MINATTICINSULATIONSHIELDCEILINGSUPPORT/FIRESTOPSPACERPI

Seite 9

VERTICALLY INTO EXISTING CHIMNEY SYSTEM( Refer to Figures 17a-17b)fig. Nº17afig. Nº17bAdapters are available to adapt from 3” L-Vent to 6” or 8” Class

Seite 10 - OWNER´S MANUAL

VERTICALLY INTO EXISTING MASONRY FIREPLACEOMNI Approvedfig. Nº19NOTE: Follow L-Vent chimney manufacturer’s instructions.• Have the masonry chimney ins

Seite 11

fig. Nº19INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY(Fig. Nº 19)NOTE: Follow L-Vent chimney manufacturer’s instructions.• Position the stove, adherin

Seite 12

OWNER’S MANUALWARNING: If your appliance is not properly installed a house fire may result.For your safety, follow the installation directions. Contac

Seite 13

TOP VIEWfig. Nº20FRONT VIEWInsertWidth:Height:Total Depth:Weight:40 in. (standard) - 45 in. (oversize)30.5 in. (standard) - 34 in. (oversize)27.4 in30

Seite 14

INSTALLATION Soul 700 Pellet InsertA - Height 20.5in to 23.5 inB - Depth (straight out) 14 inB - Depth w/ tee 19.5 inC - Hearth ex

Seite 15

WARNING:BOSCA ZC KIT REQUIRED FOR FLOOR PROTECTION ONCOMBUSTIBLE SUBFLOORING. PART #Fireplace Warning Label(Provided in accesory package - insert only

Seite 16

(USA Only) Venting into an Existing ChimneyThis pellet insert may be installed into a masonry fireplace (built to UBC 37 or ULC S628 standards) or a f

Seite 17

NOTE: Use metal plate around exhaust vent pipe and seal all edges with non-flammable insulation such as fiberglass, mineral woolor ceramic material.Do

Seite 18

1.- SORROUND PANEL ASSEMBLY (Fig. Nº27)INSTALLING SURROUND PANEL Soul 700 Pellet InsertOUTSIDE AIRTHROUGHREAR WALL12" (305 MM)MIN. ABOVE12"

Seite 19

SPECIFICATIONS Soul 700 Pellet Insertfig. Nº28fig. Nº29Flue Size 3” or 4”Floor Protection Requirement 6” From Front of Firebox opening behind doorHop

Seite 20 - (Fig. Nº20)

INSTALLATION CHECKLIST Soul 700 Pellet InsertProfessional installation of your BOSCA SOUL 700 Pellet Insert is strongly recommended. If you cho

Seite 21 - Soul 700 Pellet Insert

ON/OFF SWITCHWhen pushed, the stove will automatically ignite. No other firestarter is necessary. Theigniter will stay on for at least 10 and up to 15

Seite 22 - Bosca ZC Kit Floor Protection

When the “1” light is illuminated on the bar graph the low feed rate is at its “normal” setting.When the “1” & “4” lights are illuminated on the b

Seite 23

INTRODUCTION 3SAFETY PRECAUTIONS 4INSTALLATION 5Specifications (Soul 700 Free Standing) 5Preparation (Soul 700 Free Standing) 6Free Standing Kit Assem

Seite 24 - VENTING SYSTEM

PULL (close)PUSH (open)DAMPER CONTROL (Fig. Nº31)The damper control rod, on the stove’s lower right front side adjuststhe combustion air. This contro

Seite 25

SHUTDOWN PROCEDURETurning your BOSCA SOUL 700 Pellet Stove off is a matter of pressing the “Power button on the control panel. The red lightwill go o

Seite 26

EXTREMELY IMPORTANT – READ CAREFULLYThe stove is hot while in operation. Keep children, pets, clothing, and furniture away. Contact may cause burns

Seite 27

FAILURE TO CLEAN AND MAINTAIN THIS UNITAS INDICATED CAN RESULT IN POOR PERFORMANCE AND SAFETYHAZARDS. NEVER CLEAN WHEN HOT.NOTE: Inspect burnpot peri

Seite 28 - OPERATION

fig. Nº33 bfig. Nº33 cfig. Nº333aOWNER´S MANUAL-33-

Seite 29 - PROPER FUEL

VACUUM USEIf a vacuum is used to clean your unit, we suggest using a vacuum designed for ashes. BOSCA recommends LoveLess Ash Vac(1-800-568-394

Seite 30 - DO NOT OVERFILL HOPPER

BLOWERSCLEANING: Over time, ashes or dust may collect on the blades of both the combustion and convection blowers. The blowersshould be vacuum

Seite 31

While wearing leather gloves (or any other gloves suitable for handling broken glass), carefully remove any loose pieces of glass fromthe doorframe. D

Seite 32 - OPERATING SAFETY PRECAUTIONS

1.The hopper is out of pellets or bridgedpellets.2.-Hopper lid left open.3.-The air damper is too far open for a low feed setting.4.-The burnpot is no

Seite 33 - MAINTENANCE

1.-Air damper open too far for ignition.2. -Blockage in igniter tube or inlet for igniter tube.3.- The burnpot is not pushed completely to therear of

Seite 34

Thank you for purchasing the BOSCA SOUL 700 Pellet Stove. You are now prepared to burn wood pellets inthe most efficient, convenient way possible. To

Seite 35 - ASH DISPOSAL

STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED· GLASS “SOOTS” UP AT A VERY FAST RATE· FLAME IS LAZY, DARK, AND HAS BLACK TIPS·

Seite 36 - BLOWERS

Remove the burnpot and thoroughly clean it.Visually inspect the damper assembly. Make sure the damper plateis attached to the damper rod. When the dam

Seite 37 - TROUBLESHOOTING GUIDE

ACET-STATREMOTE5 VDCSS3BROWNBROWNPROF OF FIREREDGRAY GRAYAIR SWITCHGEAR MOTORAUGERMOLEX CONNECTORBACKIGNITERCOMMONSS10-TEMPSWITCHMANUAL RE-SETREQUIRED

Seite 38

NUMBER010203040506070809101112131415161718192021222324252829303132333435363738394041424344454647C O D E12720001127200031272000412720006127200071272

Seite 39

OWNER´S MANUAL-43-REPLACEMENT PARTS1332391415202221 BA22 O M NC E G PID F H J K L

Seite 40

OWNER´S MANUAL-44-REPLACEMENT PARTS1332391415202221 BA22D F ECG H K MJ L I

Seite 41

OWNER´S MANUAL-45-STATEMENT OF POLICY:BOSCA warrants its products from component failure and defects in material or workmanship per the terms of the w

Seite 42 - ELECTRICAL DIAGRAM

This Warranty is void if the stove has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or otherdamaging chemicals. It

Seite 43 - REPLACEMENT PARTS

BOSCA CHILE S.A.Av. Américo Vespucio 2077HuechurabaSantiago - ChileTelephone : (56) 2 3288500Fax: (56) 2 624 1891www.boscastoves.comMade in Chile

Seite 44

§ Do not operate your stove if you smell smoke coming from it. Turn it off, do not unplug, monitor it, and call your dealer.§ Never use gasoline, ga

Seite 45

INSTALLATIONSPECIFICATIONS Soul 700 Pellet Free StandingTOP VIEWfig. Nº130.2 in.(767 mm.)FRONT VIEW26.8 in.34.6 in.(683 mm.)(880 mm.)Freestanding26.8

Seite 46 - LIFETIME LIMITED WARRANTY

Factory packaging must be removed, and some minor assembly work is required prior to installation. Access to the rear of thestove is necessary.1.- PED

Seite 47 - IMPORTANT INFORMATION

3.- PEDESTAL ASSEMBLY (fig. Nº4)a.- Unpack pedestal assembly.b.- Lay pedestal assembly on it's back.c.- Line up four (1/4" hex head) bolts t

Seite 48 - Made in Chile

6.- HOPPER TOP ASSEMBLY (fig. Nº7)5. SIDE PANEL ASSEMBLY (fig. Nº6)a.- Unpack side panels.b.- Left side panel has hopper switch located attop front.c